Performance of Spleen Stiffness Measurement in Prediction of Clinical Significant Portal Hypertension: A Meta-Analysis

Jinzhen Song,Jianbo Huang,He Huang,Shiyu Liu,Yan Luo
DOI: https://doi.org/10.1016/j.clinre.2017.11.002
IF: 3.189
2018-01-01
Clinics and Research in Hepatology and Gastroenterology
Abstract:Aim: Our purpose was to evaluate the correlation between spleen stiffness (SS) measured by ultrasound-based elastography and hepatic venous pressure gradient (HVPG) and assess the accuracy of SS in detecting clinical significant portal hypertension (CSPH) and severe portal hypertension. Method: Nine studies were included from thorough literature research and selection processes. A random model was used to analyze the correlation between HVPG and SS. We adopted the bivariate mixed effects model to assess the diagnostic performance. Results: Regarding to correlation between SS and HVPG, the summary correlation coefficient was 0.72 (95% confidence interval [CI], 0.63-0.80). In detection of CSPH, the sensitivity, specificity, AUC and DOR were: 0.88 (0.70-0.96), 0.84 (0.72-0.92), 0.92 (0.89-0.94) and 38 (17-84) for CSPH, respectively; and 0.92 (0.82-0.96), 0.79 (0.72-0.85), 0.87 (0.84-0.90) and 41 (17-100) for severe portal hypertension, respectively. Conclusion: Correlation between SS and HVPG was good. Although SS showed good sensitivity and specificity, the different cut-off values and techniques among studies might limit the impact of our results on clinical practice. Therefore, more high-quality prospective studies are required to evaluate the role of SS in predicting portal hypertension. (C) 2017 Elsevier Masson SAS. All rights reserved.