Removal of ammonia nitrogen using polyurethane hydrogel immobilized nitrobacteria at low temperature

dong yamei,zhang zhenjia,li jun,wang ting,feng yanan,he dannong
2015-01-01
Abstract:The immobilized nitrobacteria pellets was prepared from polyurethane hydrogel and acclimatized with simulated ammonia nitrogen wastewater in an up-flow inner circulation reactor. Factors affecting nitrification characteristics of immobilized nitrobacteria under low temperature such as temperature fluctuation and hydraulic retention time were investigated. The accumulation of nitrite nitrogen and nitrate nitrogen in the whole reaction process was also investigated. The results showed that the ammonia nitrogen removal rate of polyurethane immobilized nitrobacteria decreased from 97% to 48% when the concentration of influent ammonia nitrogen was 40 mg / L,HRT was 4 h and the water temperature was reduced from 22℃ to 10℃. The removal rate of ammonia nitrogen could reach 75% when HRT was adjusted at 10℃. The concentration of influent ammonia nitrogen was reduced to 15 mg / L and HRT was set to 4 h the ammonia nitrogen removal rate can keep stable around 80%when temperature varied within a range of 7 ~ 13℃. The sufficient DO was provided in the whole process and the accumulation of nitrite was not observed.