Energy Consumption Analysis and Management Strategies for the Dairy Farm in India Towards Sustainable Development
M. Abragam Siyon Sing M. Marsaline Beno St.Xavier's Catholic College of Engineering,Chunkankadai,IndiaM Abragam Siyon Sing is a part-time research scholar and assistant professor in the department of electrical and electronics engineering,at St.Xavier's Catholic College of Engineering. He is a certified energy manager,at the Bureau of Energy Efficiency,Govt. of India. His areas of interest include energy management and electrical machinesM Marsaline Beno is a professor in the department of electrical and electronics engineering,at St.Xavier's Catholic College of Engineering. He is a certified energy manager,at the Bureau of Energy Efficiency,Govt. of India. His areas of interest include electrical drives and control,smart grid,and soft computing techniques. He has published more than 30 journal articles. He has received Education Excellence Award in 2021. He is a life member of the Indian Society for Technical Education and a member of the Institution of Engineering and Technology (UK) and the Institute of Electrical and Electronics Engineering (USA). Email:
DOI: https://doi.org/10.1080/03772063.2024.2359006
IF: 1.8768
2024-06-03
IETE Journal of Research
Abstract:Environmental pollution and the rapid decline in the availability of fossil fuels are the major concerns of the electric power industry in recent years. Effective utilization of electrical energy is the need of the hour in building the nation towards sustainable development. This study presents the energy consumption analysis and management performed in a diary firm located in Tamil Nadu, India. Initially, the energy usage of the firm is estimated based on its electricity bills, meter readings, and survey followed by detailed energy consumption analysis and evaluation. The study employs guidelines provided by the Indian Bureau of Energy Efficiency for energy management. The detailed analysis performed finds scopes for improvement in efficient energy usage. Numerical analysis shows that implementation of proposed action plans that include installation of automatic power factor correction, replacement of overheating equipment, and replacement of lighting systems with energy-efficient lighting would save annual energy of 123.96 kWh which in turn results in the reduction of annual CO 2 emission by 117.76 tonnes. Furthermore, this paper also proposes a novel optimal process scheduling which optimally schedules different processes in the firm without affecting productivity. This makes an additional savings of INR 4,23,360 per annum in the energy cost by minimizing the maximum demand of the firm with zero investment. A comparison of the proposed approach with existing methodologies available in the literature shows the effectiveness of the proposed technique.
telecommunications,engineering, electrical & electronic