In Situ and Intraoperative Detection of the Ureter Injury Using a Highly Sensitive Piezoresistive Sensor with a Tunable Porous Structure
Shan Wang,Guorui Chen,Bing Yao,Adrian J. Y. Chee,Zongrong Wang,Piyi Du,Shaoxing Qu,Alfred C. H. Yu
DOI: https://doi.org/10.1021/acsami.0c22791
2021-04-30
Abstract:Iatrogenic ureteral injury, as a commonly encountered problem in gynecologic, colorectal, and pelvic surgeries, is known to be difficult to detect in situ and in real-time. Consequently, this injury may be left untreated, thereby leading to serious complications such as infections, renal failure, or even death. Here, high-performance tubular porous pressure sensors were proposed to identify the ureter in situ intraoperatively. The electrical conductivity, mechanical compressibility, and sensor sensitivity can be tuned by changing the pore structure of porous conductive composites. A low percolation threshold of 0.33 vol % was achieved due to the segregated conductive network by pores. Pores also lead to a low effective Young's modulus and high compressibility of the composites and thus result in a high sensitivity of 448.2 kPa<sup>–1</sup> of sensors, which is consistent with the results of COMSOL simulation. Self-mounted on the tip of forceps, the sensors can monitor tube pressures with different frequencies and amplitudes, as demonstrated using an artificial pump system. The sensors can also differentiate ureter pulses from aorta pulses of a Bama minipig in situ and in real-time. This work provides a facile, cost-effective, and nondestructive method to identify the ureter intraoperatively, which cannot be effectively achieved by traditional methods.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c22791?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c22791</a>.SEM image of contacted pores formed by removing SiO<sub>2</sub> microspheres; SEM image of PDMS/CNT composites; SEM images and particle size distribution of SiO<sub>2</sub> microspheres; CNT distribution in the pure PDMS/CNT composite and porous composite; schematic view of the microstructure of the conductor-filled polymer composites; setup for the response time measurement and voltage outputs of the sensor; photograph of the artificial ureter pump system and signal recording; and monitoring the ureter contraction peristalsis of a Bama minipig in real-time (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c22791/suppl_file/am0c22791_si_001.pdf">PDF</a>)Generation of distinguished current responses to the varying flow rates using a pressure sensor (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c22791/suppl_file/am0c22791_si_002.avi">AVI</a>)Periodical occurrence of current peaks with a frequency of about 6 times per minute (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c22791/suppl_file/am0c22791_si_003.avi">AVI</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology