Instrument for insulation conditions detection of roof insulator on high-speed-train

ZHANG Xueqin,YIN Guolong,GAO Guoqiang,SHAO Mengchun,YIN Xianbin,LI Chunmao,WU Guangning
DOI: https://doi.org/10.15878/j.cnki.instrumentation.2014.02.006
2014-01-01
Abstract:With the rapid development of high-speed-railw ay,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument w ith high reliability w hich can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogow ski coil sensor for better leakage current signal. To avoid the fluctuation from railw ay pow er supply,four modules are set to filter the pow er supply w aveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation w hen leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator.更多还原
What problem does this paper attempt to address?