Heart sound signal envelope extraction based on modified Viola integral method

Guo Xingming,Jiang Hong,Zheng Yineng
DOI: https://doi.org/10.19650/j.cnki.cjsi.2016.10.023
2016-01-01
Abstract:Heart sound is one of the most important physiological signals evaluating human heart function,analyzing heart sound signal characteristic is of great significance for the early diagnosis and treatment of heart disease.In this paper,the Hilbert-Huang transform, normalized Shannon energy and Viola integral method are used to extract the characteristic envelope of heart sound signal.Aiming at the deficiency of Viola integral method,considering the characteristic that Shannon energy method can restrain the high and low intensity signals,a modified heart sound signal envelope extraction method is proposed.Finally,the threshold method is adopted to achieve the heart sound signal segmentation.The modified Viola integral method was adopted to extract the characteristic envelopes and conduct segmentation processing of 55 cases of heart sound signals,and the experiment result shows that the proposed method can effectively extract the envelopes of normal and abnormal heart sound signals,the segmentation accuracy is 1 00% for normal heart sound signal and 95.32% for abnormal heart sound signal,which indicates that the modified Viola integral method is suitable for heart sound signal segmentation.
What problem does this paper attempt to address?