Design and analysis of air-coupled capacitive micromachined ultrasonic transducers

Zhang Hui,Zhao Xiaonan,Zhang Wen,Zeng Zhoumo
DOI: https://doi.org/10.19650/j.cnki.cjsi.2016.10.007
2016-01-01
Abstract:Traditional Capacitive Micromachined Ultrasonic Transducer (CMUT)adopts sealed cavity;there exists pressure difference across the vibrating membrane,which makes it difficult to vibrate and leads to require high DC bias voltage.Meanwhile,the narrow cavity hinders the membrane vibration,which reduces the electromechanical coupling efficiency.Aiming at this problem,a vented vibration membrane structure was designed,which eliminates the adverse effect caused by sealed cavity.The influence of the size and position of the etch holes on the frequency characteristics of CMUT was studied.The fabrication process based on surface silicon sacrificial technology was designed;a 64-element CMUT array was fabricated.The impedance calibration of single element in the CMUT array was conducted.Then the resonant characteristic of the vibration membrane was tested,and the consistency of the elements in the array was also tested.Analysis and experiment results demonstrate that the CMUT with vented vibrition membrane and non-sealed cavity can satisfy the design requirements,and the elements in the array have satisfactory consistency.
What problem does this paper attempt to address?