Fabry-Perot Interferometric High-Temperature Sensing Up To 1200 Degrees C Based On A Silica Glass Photonic Crystal Fiber

Haihu Yu,Ying Wang,Jian Ma,Zhou Zheng,Zhuozhao Luo,Yu Zheng
DOI: https://doi.org/10.3390/s18010273
IF: 3.9
2018-01-01
Sensors
Abstract:A Fabry-Perot interferometric sensor for temperature measurement was fabricated based on a silica glass solid-core photonic crystal fiber with a central air-bore. By splicing a stub of photonic crystal fiber to a standard single-mode fiber, an intrinsic Fabry-Perot cavity was formed inside the photonic crystal fiber. Sensing experiment results show that the sensor can work stably for a consecutive 24 h under temperatures up to 1100 degrees C, and the short-term operation temperature can reach as high as 1200 degrees C (<30 min). In the measurement range of 300-1200 degrees C, the temperature sensitivity of the peak wavelength shift can reach as high as 15.61 pm/degrees C, with a linearity of 99.76%. The presented interferometric sensor is compact in size and possesses advantages such as an extended working range and high sensitivity, showing promising application prospects.
What problem does this paper attempt to address?