An UHPLC–MS/MS Method for Simultaneous Quantification of Human Amyloid Beta Peptides Aβ1-38, Aβ1-40 and Aβ1-42 in Cerebrospinal Fluid Using Micro-Elution Solid Phase Extraction

Ping-ping Lin,Wei-li Chen,Fei Yuan,Lei Sheng,Yu-jia Wu,Wei-wei Zhang,Guo-qing Li,Hong-rong Xu,Xue-ning Li
DOI: https://doi.org/10.1016/j.jchromb.2017.10.047
IF: 4.601
2017-01-01
Journal of Chromatography A
Abstract:Amyloid beta (A beta) peptides in cerebrospinal fluid are extensively estimated for identification of Alzheimer's disease (AD) as diagnostic biomarkers. Unfortunately, their pervasive application is hampered by interference from A beta propensity of self-aggregation, nonspecifically bind to surfaces and matrix proteins, and by lack of quantitive standardization. Here we report on an alternative Ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous measurement of human amyloid beta peptides A beta 1-38, A beta 1-40 and A beta 1-42 in cerebrospinal fluid (CSF) using micro-elution solid phase extraction (SPE). Samples were pre-processing by the mixed-mode micro-elution solid phase extraction and quantification was performed in the positive ion multiple reaction monitoring (MRM) mode using electrospray ionization. The stable-isotope labeled A beta peptides N-15(51)- A beta 1-38, N-15(53)- A beta 1-40 and N-15(55)- A beta 1-42 peptides were used as internal standards. And the artificial cerebrospinal fluid (ACSF) containing 5% rat plasma was used as a surrogate matrix for calibration curves. The quality control (QC) samples at 0.25, 2 and 15 ng/mL were prepared. A "linear" regression (1/x(2) weighting): y = ax + b was used to fit the calibration curves over the concentration range of 0.1-20 ng/mL for all three peptides. Coefficient of variation (CV) of intra-batch and inter-batch assays were all less than 6.44% for A beta 1-38, 6.75% for A beta 1-40 and 10.74% for A beta 1-42. The precision values for all QC samples of three analytes met the acceptance criteria. Extract recoveries of A beta 1-38, A beta 1-40 and A beta 1-42 were all greater than 70.78%, both in low and high QC samples. The stability assessments showed that QC samples at both low and high levels could be stable for at least 24 h at 4 degrees C, 4 h at room temperature and through three freeze-thaw cycles without sacrificing accuracy or precision. And no significant carryover effect was observed. This validated UHPLC/MS/MS method was successfully applied to the quantitation of A beta peptides in real human CSF samples. Our work may provide a reference method for simultaneous quantitation of human A beta 1-38, A beta 1-40 and A beta 1-42 from CSF.
What problem does this paper attempt to address?