A SVM Method for Continuous Blood Pressure Estimation from a PPG Signal.

Yue Zhang,Zhimeng Feng
DOI: https://doi.org/10.1145/3055635.3056634
2017-01-01
Abstract:There is not always a linear relationship between the blood pressure and the pulse duration obtained from photoplethysmography (PPG) signal. In order to estimate the blood pressure from the PPG signal, A Support Vector Machine (SVM) method for continuous blood pressure estimation from a PPG Signal is applied in this paper. Training data were extracted from The University of Queensland Vital Signs Dataset for better representation of possible pulse and pressure variation. In total there were more than 7000 heartbeats and 9 parameters to be extracted from each other for analysis, then these features were defined as the input vector for training. The comparison between estimated and reference values shows better accuracy than the linear regression method and also shows better accuracy than the ANN method in diastolic blood pressure, which brings great significance in the field of mobile wearable.