A Gyro-Aided Strapdown Triaxial Magnetometer Calibration Method Robust to Gyro Bias
Jihao Liu,Xihai Li,Ying Zhang,Aimin Du,Xiaoniu Zeng,Yong Yang
DOI: https://doi.org/10.1109/tim.2021.3060594
IF: 5.6
2021-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:Geomagnetic vector field is always measured by a strapdown triaxial magnetometer on a vehicle. The magnetometer measurements are polluted by the magnetometer inherent errors, misalignment error, and vehicle-generated magnetic inferences. With the aid of absolute attitude information from the gyro, the calibration accuracy has been proved to be greatly improved, especially for vector measurements. However, the performance of calibration methods is greatly affected by the gyro bias, which causes error accumulated over time in the absolute attitude information. In this work, we propose an improved calibration method robust to gyro bias based on relative attitude information from the gyro. Simulation results indicated that the proposed method can estimate the calibration parameters more accurately and stably than the traditional method when the gyro bias exists. The influence on the calibration accuracy of the different parts of the gyro bias is also analyzed by simulation. Experiment using a low-cost gyro proved that the proposed method can effectively improve the estimation accuracy of the calibration parameters, as the influence on the traditional method of the gyro bias is 2–3 orders of magnitude higher than that on the proposed method.
engineering, electrical & electronic,instruments & instrumentation