A 17 Mw 3-to-5 GHz Duty-Cycled Vital Sign Detection Radar Transceiver with Frequency Hopping and Time-Domain Oversampling.

Xican Chen,Yiyu Shen,Zhicheng Wang,Woogeun Rhee,Zhihua Wang
DOI: https://doi.org/10.1109/tcsi.2016.2623763
2016-01-01
IEEE Transactions on Circuits and Systems I Regular Papers
Abstract:This paper presents a low power interference-robust radar transceiver architecture for noncontact vital sign detection and mobile healthcare applications. A duty-cycled transceiver design is proposed to significantly reduce power consumption of front-end circuits. Occupying 3-to-5 GHz band with four 500 MHz sub-channels, the radar mitigates the narrowband interference (NBI) problem with the frequency hopping scheme. In the time domain, the $\Delta \Sigma $ TDC is employed to achieve fine ranging resolution with noise shaped oversampling. The transceiver implemented in 65 nm CMOS consumes 17.2 mW from a 1.0-V supply when duty-cycled and achieves an RMS detection accuracy of 5.68 mm.