P-wave Detection in Electrocardiograms Based on Bilateral Accumulative Area

Ri-qing Chen,Jian Wu,Yong-gui Han
2015-01-01
Abstract:P-wave duration in electrocardiogram is important evidence of atrial disease analysis in clinic diagnosis. It is critical for accurate delineation of P wave. This study presented an efficient and robust detection method for P-wave boundary points on the basis of bilateral accumulative area with combination of the multi-window and 12-lead synchronous detection. First of all, through multi-scale screening, the optimal extreme points are picked out from all extreme points of different window lengths. And the 12-lead synchronous detection is used for P-wave location matching. The results of the proposed method were evaluated on the dataset-3 of the standard CSE database. As a result, the value of sensitivity Se = 99% was obtained for the detection of P-wave.
What problem does this paper attempt to address?