Simulation for Harmonic Analysis of an Integrated Power System.

De-jia Zhou,Ru-quan Mao,Ya-ping Zhuang,Shan-ming Wang
DOI: https://doi.org/10.1007/978-981-10-2663-8_29
2016-01-01
Abstract:Modeling and Simulation is an effective way to predict the behaviors of Shipboard Integrated Power System (IPS). This paper presents the methods applying simulink blockset to building the models of twelve-phase synchronous machine and twelve-phase voltage-fed inverter, whereby the hybrid simulation method using SimPowerSystem blocks and Simulink models for the harmonic analysis of the IPS simulation is proposed. The results of the harmonic analysis of the system which is a system of the AC-DC-AC driving twelve-phase synchronous motor show that the convenient eleventh and thirteenth LC filters can improve deeply the Total Harmonic Distortion (THD) of line current in the AC source of system, and with the loads increased, the THD of the line voltage of the AC source is increased, on the contrary, the THD of the current of AC source is decreased.
What problem does this paper attempt to address?