Improved Measurement of the Differential Polarizability Using Co-Trapped Ions

Yuan-Fei Wei,Si-Jia Chao,Kai-Feng Cui,Cheng-Bin Li,Shi-Cheng Yu,Han Zhang,Hua-Lin Shu,Jian Cao,and Xue-Ren Huang
DOI: https://doi.org/10.1103/physrevlett.133.033001
IF: 8.6
2024-07-19
Physical Review Letters
Abstract:We present a novel approach for measuring the differential static scalar polarizability of a target ion utilizing a "polarizability scale" scheme with a reference ion co-trapped in a linear Paul trap. The differential static scalar polarizability of the target ion can be precisely extracted by measuring the ratio of the ac Stark shifts induced by an add-on infrared laser shed on both ions. This method circumvents the need for the calibration of the intensity of the add-on laser, which is usually the bottleneck for measurements of the polarizability of trapped ions. As a demonstration, Al+27 (the target ion) and Ca+40 (the reference ion) are used in this work, with an add-on laser at 1068 nm injected into the ion trap along the trap axis. The differential static scalar polarizability of Al+27 is extracted to be 0.416(14) a.u. by measuring the ratio of the ac Stark shifts of both ions. Compared to the most recent result [ Phys. Rev. Lett. 123 , 033201 (2019)], the relative uncertainty of the differential static scalar polarizability of Al+27 is reduced by approximately a factor of 4, to 3.4%. This improvement is expected to be further enhanced by using an add-on laser with a longer wavelength. https://doi.org/10.1103/PhysRevLett.133.033001 © 2024 American Physical Society
physics, multidisciplinary
What problem does this paper attempt to address?