Robust Particle Filtering With State Transition Uncertainties: A Student’s t Disturbance Observer-Based Approach

Wenshuo Li,Xin Liu,Lei Guo
DOI: https://doi.org/10.1109/tim.2021.3109393
IF: 5.6
2021-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:This article is concerned with robust particle filtering (PF) for nonlinear systems with state transition uncertainties. The uncertainty under consideration is characterized in part by an additive uncertainty term (AUT) in the state transition equation and in part by the parametric uncertainty in the probability distribution of process noises. To maintain the sampling efficiency of the PF algorithm in the presence of AUT, the disturbance observer (DO)-based PF approach is adopted, which consists of the DO for real-time AUT reconstruction and a modified PF with AUT-compensated sampling. Instead of using the traditional Kalman filter-based DO, a novel student's <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="0.84ex" height="2.009ex" style="vertical-align: -0.338ex;" viewBox="0 -719.6 361.5 865.1" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-74" x="0" y="0"></use></g></svg></span> DO is proposed to handle uncertain noise parameters and achieve robust disturbance estimation. The enhanced robustness of the proposed method, named student's <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="0.84ex" height="2.009ex" style="vertical-align: -0.338ex;" viewBox="0 -719.6 361.5 865.1" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-74" x="0" y="0"></use></g></svg></span> DO-based robust PF, has been demonstrated via numerical example. Furthermore, experimental tests on the skylight polarization-aided attitude and heading reference system show that the standard deviation of our method decreases by over 40% as compared with the conventional PF.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-74" d="M26 385Q19 392 19 395Q19 399 22 411T27 425Q29 430 36 430T87 431H140L159 511Q162 522 166 540T173 566T179 586T187 603T197 615T211 624T229 626Q247 625 254 615T261 596Q261 589 252 549T232 470L222 433Q222 431 272 431H323Q330 424 330 420Q330 398 317 385H210L174 240Q135 80 135 68Q135 26 162 26Q197 26 230 60T283 144Q285 150 288 151T303 153H307Q322 153 322 145Q322 142 319 133Q314 117 301 95T267 48T216 6T155 -11Q125 -11 98 4T59 56Q57 64 57 83V101L92 241Q127 382 128 383Q128 385 77 385H26Z"></path></defs></svg>
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?