Dragging 3D printing technique controls pore sizes of tissue engineered blood vessels to induce spontaneous cellular assembly
Hun-Jin Jeong,Hyoryung Nam,Jae-Seok Kim,Sungkeon Cho,Hyun-Ha Park,Young-Sam Cho,Hyungkook Jeon,Jinah Jang,Seung-Jae Lee
DOI: https://doi.org/10.1016/j.bioactmat.2023.07.021
IF: 18.9
2023-10-06
Bioactive Materials
Abstract:Highlights • Sufficient mechanical properties and endothelium are keypoint of the successful small artificial blood vessel graft. • A porous, free-form, multi-layered, tubular small-diameter vessel construct using the dragging 3D printing technique. • Induced spontaneous cellular assembly endothelium for small-diameter vessels without any additional intervention. • Sufficiently withstanding various external stress for graft. To date, several off-the-shelf products such as artificial blood vessel grafts have been reported and clinically tested for small diameter vessel (SDV) replacement. However, conventional artificial blood vessel grafts lack endothelium and, thus, are not ideal for SDV transplantation as they can cause thrombosis. In addition, a successful artificial blood vessel graft for SDV must have sufficient mechanical properties to withstand various external stresses. Here, we developed a spontaneous cellular assembly SDV (S-SDV) that develops without additional intervention. By improving the dragging 3D printing technique, SDV constructs with free-form, multilayers and controllable pore size can be fabricated at once. Then, The S-SDV filled in the natural polymer bioink containing human umbilical vein endothelial cells (HUVECs) and human aorta smooth muscle cells (HAoSMCs). The endothelium can be induced by migration and self-assembly of endothelial cells through pores of the SDV construct. The antiplatelet adhesion of the formed endothelium on the luminal surface was also confirmed. In addition, this S-SDV had sufficient mechanical properties (burst pressure, suture retention, leakage test) for transplantation. We believe that the S-SDV could address the challenges of conventional SDVs: notably, endothelial formation and mechanical properties. In particular, the S-SDV can be designed simply as a free-form structure with a desired pore size. Since endothelial formation through the pore is easy even in free-form constructs, it is expected to be useful for endothelial formation in vascular structures with branch or curve shapes, and in other tubular tissues such as the esophagus. Graphical abstract Download : Download high-res image (545KB) Download : Download full-size image
engineering, biomedical,materials science, biomaterials