Efficient Microfluidic-Based Air Sampling/Monitoring Platform for Detection of Aerosol SARS-CoV-2 On-site

Huiwen Xiong,Xin Ye,Yang Li,Jun Qi,Xueen Fang,Jilie Kong
DOI: https://doi.org/10.1021/acs.analchem.0c05154
IF: 7.4
2021-02-26
Analytical Chemistry
Abstract:Airborne pathogens have been considered as highly infectious and transmittable between humans. With the pandemic outbreak of the coronavirus disease 2019 (COVID-19), an on-site diagnostic system-integrated airborne pathogen-monitoring machine is recommended by experts for preventing and controlling the early stage β-coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread. In this work, a small-volume rotating microfluidic fluorescence chip-integrated aerosol SARS-CoV-2 sampling system was constructed to satisfy the demand for rapid on-site sample collection and detection of SARS-CoV-2. The rotating microfluidic fluorescence system with small volume has very high sensitivity in the detection of SARS-CoV-2 (detection limit of 10 copies/μL with the shortest Ct value of 15 min), which is comparable to reverse transcription polymerase chain reaction (RT-PCR). The precision variation coefficients within/between batches are very low [coefficient of variation (CV) % ≤ 5.0%]. Our work has passed the comprehensive inspection of the microfluidic chip performance by the Shanghai Medical Device Testing Institute [National Medical Inspection (Design) no. 4408] and successfully tested 115 clinical samples. The integrated system exhibits 100% specificity, high sensitivity (10 copies/μL), and good precision (CV % ≤ 5.0%) in the rapid detection of SARS-CoV-2, thus realizing rapid monitoring and diagnostics of SARS-CoV-2 nucleic acid on-site.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c05154?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c05154</a>.Photograph of the microfluidic chip; primer sets targeting ORF1ab and N for SARS-CoV-2 integrated microfluidic assay; ratio optimization between the inner primer and outer primer of ORF1ab and N; optimization of the experimental condition targeting ORF1ab and N; dilutions for SARS-CoV-2 pseudoviral samples targeting ORF1ab and N; detection Results of SARS-CoV-2; detection limit verification of SARS-CoV-2 targeting OFR1ab; different concentrations of SARS-CoV-2 pseudovirus; reproducibility detection results of the ORF1ab target and N gene target; concentrations of various interfering substances; detection results of interfering substances; detection results of the novel coronavirus sample; κ analysis; and analysis of 95% CIs (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c05154/suppl_file/ac0c05154_si_001.pdf">PDF</a>).This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?