Abstract:Objective To evaluate the fetal right ventricular function by using full volume real-time three-dimensional echocardiography(RT-3DE). Methods The fetal right ventricular volumes of 109 normal fetuses were outlined and calculated by Shimanaki rule, Simpson's method and full-volume RT-3DE. The right ventricular end-diastolic volume (EDV), endsystolic volume(ESV),stroke volume(SV),ejection fraction(EF) and cardiac output(CO) measured by three different methods were compared. Results The EDV,ESV,SV,CO were significantly different among three methods(F=31.22,23.30, 31.67,32.61, P0.05) except the EF(F=1.56,P0.05) . EDV, ESV, SV, CO were significantly different except EF between Shimanaki and Simpson method as well as between Shimanaki and RT-3DE(t=6.57, 5.64, 6.66, 6.76; 7.10, 6.25, 7.11, 7.21, P0.05). Compared with RT-3DE, the EDV, ESV, SV, CO, EF of Simpson were not significantly different (t=0.53,0.61,0.44,0.45, 0.52, P0.05). The Kappa value of RT-3DE was higher than that of the Simpson. Conclusions RT-3DE is an accurate and reliable method to make a comprehensive, holistic evaluation of fetal right ventricular function.