Experimental Study on Internal Flow of a Mini Centrifugal Pump by PIV Measurement

Yulin Wu,Huijing Yuan,Jie Shao,Shuhong Liu
DOI: https://doi.org/10.5293/ijfms.2009.2.2.121
2009-01-01
International Journal of Fluid Machinery and Systems
Abstract:Abstract The internal flow field in a centrifugal pump working at the several flow conditions has been measured by using the particle image velocimetry (PIV) technique with the laser induced fluorescence (LIF) particles and the refractive index matched (RIM) facilities. The impeller of the centrifugal pump has an outlet diameter in 100mm, and consists of six two-dimensional curvature backward swept blades of constant thickness. Measured results give reliable flow patterns in the pump. It is obvious that application of LIF particle and RIM are the key methods to obtain the right PIV measured results in pump internal flow Keywords : Centrifugal pump, PIV, laser induced fluorescence, refractive index matched. 1. Introduction Experimental flow studies are often conducted using optical diagnostic techniques including qualitative flow visualization methods, laser Doppler velocimetry (LDV), and more recently full field methods such as particle image velocimetry (PIV) for velocity field measurements, and laser induced fluorescence (LIF) for concentration field measurements. A difficulty common to all these methods is the refraction of light passing through gas-solid or liquid-solid interfaces of model and/or test section walls (Budwig, 1994)
What problem does this paper attempt to address?