Removal of volatile fatty acid in landfill leachate by the microwave-hydrothermal method

lie yang,zhulei chen,jinfeng yang,yong liu,jia wang,yingjian yu,xiaoming gao
DOI: https://doi.org/10.1080/19443994.2013.803712
IF: 1.1
2014-01-01
Desalination and Water Treatment
Abstract:In this study, we report on the rising concern with landfill facility is the safe disposal of leachate and high volatile fatty acid (VFA) concentration in leachate provokes the inhibition of biochemical treatment of landfill leachate to the elimination of these serious problems, a microwave-hydrothermal (MH) method has been employed. This new process, named MH method, was developed for the removal of VFA from leachate. The effects of pH, microwave (MW) power, radiation time, and aeration on the removal were investigated. pH and MW radiation time presented significant influence on the removal of VFA. The optimal removal obtained with 625W power at initial pH approximate to 7.2 in 8 min. Aeration presented slight enhancement on the removal. With the optimal operating parameters, the removal of VFA in landfill leachate could reach approximate to 30.7% with aeration. The mechanism of VFA removal was proposed as the evaporation of molecular VFA by MW radiation. Compared with heating with an electric oven, MW radiation obtained higher VFA removal. The results shows both thermal and nonthermal effects contributed to the removal of VFA and thermal effects played a more significant role on the removal. It could be proposed that MW radiation could significantly alleviate negative effects of VFA on further treatment of leachate and act as an effective pretreatment method of leachate.
What problem does this paper attempt to address?