Calibration of the RPC Charge Readout in the ARGO-YBJ Experiment with the Iso-Gradient Method

B. Bartoli,P. Bernardini,X. J. Bi,P. Branchini,A. Budano,P. Camarri,Z. Cao,R. Cardarelli,S. Catalanotti,S. Z. Chen,T. L. Chen,P. Creti,S. W. Cui,B. Z. Dai,A. D'Amone,Danzengluobu,I. De Mitri,B. D'Ettorre Piazzoli,T. Di Girolamo,G. Di Sciascio,C. F. Feng,Zhaoyang Feng,Zhenyong Feng,Q. B. Gou,Y. Q. Guo,H. H. He,Haibing Hu,Hongbo Hu,M. Iacovacci,R. Iuppa,H. Y. Jia,Labaciren,H. J. Li,G. Liguori,C. Liu,J. Liu,M. Y. Liu,H. Lu,L. L. Ma,X. H. Ma,G. Mancarella,S. M. Mari,G. Marsella,D. Martello,S. Mastroianni,P. Montini,C. C. Ning,M. Panareo,L. Perrone,P. Pistilli,F. Ruggieri,P. Salvini,R. Santonico,P. R. Shen,X. D. Sheng,F. Shi,A. Surdo,Y. H. Tan,P. Vallania,S. Vernetto,C. Vigorito,H. Wang,C. Y. Wu,H. R. Wu,L. Xue,Q. Y. Yang,X. C. Yang,Z. G. Yao,A. F. Yuan,M. Zha,H. M. Zhang,L. Zhang,X. Y. Zhang,Y. Zhang,J. Zhao,Zhaxiciren,Zhaxisangzhu,X. X. Zhou,F. R. Zhu,Q. Q. Zhu,G. Zizzi
DOI: https://doi.org/10.1016/j.nima.2015.02.034
2015-01-01
Abstract:The ARGO-YBJ experiment is a full coverage array of Resistive Plate Chambers (RPCs) with an active area of 5800m2. In order to eliminate the response difference of the charge readout from the RPCs, a calibration procedure is carried out with the iso-gradient method. This method also allows the extension of the absolute calibration with the muon telescope including scintillation detectors to all the RPCs in the array. The overall systematic uncertainty in measurements of the number of particles by the RPCs is 10.7%. In general, the method gives results consistent with those from a totally different approach also used in the experiment.
What problem does this paper attempt to address?