Experimental Investigation of the Hysteretic Performance of Self-Centering Buckling-Restrained Braces with Friction Fuses

Qin Xie,Zhen Zhou,Shao-Ping Meng
DOI: https://doi.org/10.1016/j.engstruct.2019.109865
IF: 5.582
2019-01-01
Engineering Structures
Abstract:The dual-tube self-centering buckling-restrained brace (SC-BRB) is a new bracing system with self-centering and energy dissipation capacity. The current dual-tube SC-BRB is limited by the elastic elongation of the tendons. When the lateral deformation of existing dual-tube SC-BRBs exceeds 2.6% of a typical building story height, the tendons will be fractured, and this fracture will lead to a sudden drop of the bearing capacity of the brace and loss of the self-centering capacity. In this paper, an SC-BRB with a friction fuse (SC-BRB-FS) is proposed by introducing a friction device at the end of the brace to increase the deformation capacity of the dual-tube SC-BRB. At the same time, two bracing specimens are built for a quasi-static test. Activation of the friction fuse can efficiently increase the deformation capacity of the brace. When the displacement reaches 36 mm (corresponding to a story drift of 4%), the tendons are still not damaged. The nonlinear dynamic time-history analysis of the structure shows that compared with the fracture of tendons, the use of a friction fuse not only restrains the soft-story effect and reduces the collapse probability of the structure but also reduces the residual deformation of the structure.