Astigmatism compensation in mode-cleaner cavities for the next generation of gravitational wave interferometric detectors

P BARRIGA,C ZHAO,D BLAIR
DOI: https://doi.org/10.1016/j.physleta.2005.03.042
IF: 2.707
2005-01-01
Physics Letters A
Abstract:Interferometric gravitational wave detectors use triangular ring cavities to filter spatial and frequency instabilities from the input laser beam. The next generation of interferometric detectors will use high laser power and greatly increased circulating power inside the cavities. The increased power inside the cavities increases thermal effects in their mirrors. The triangular configuration of conventional mode-cleaners creates an intrinsic astigmatism that can be corrected by using the thermal effects to advantage. In this Letter we show that an astigmatism free output beam can be created if the design parameters are correctly chosen.
What problem does this paper attempt to address?