Evaluating the safe limit of large-aperture potassium dihydrogen phosphate crystals associated with transverse stimulated Raman scattering

wei han,yong xiang,fuquan li,fang wang,lidan zhou,junpu zhao,bin feng,kuixing zheng,qihua zhu,xiaofeng wei,wanguo zheng,mali gong
DOI: https://doi.org/10.1364/AO.54.004167
IF: 1.9
2015-01-01
Applied Optics
Abstract:We propose a process to evaluate the safe limit of large-aperture DKDP crystals associated with transverse stimulated Raman scattering (TSRS) at the wavelength of 351 nm. The DKDP crystals' safety can be assured by controlling the intensity of TSRS-scattering light to the same order of that of Rayleigh-scattering light. We use an optical fiber sensor system to detect side-scattering light in the DKDP and compare the intensity between Raman-and Rayleigh-scattering light. By defining the threshold intensity as a condition in which the intensity ratio between transverse Raman-scattering light and Rayleigh-scattering light exceeds 1, we obtain the threshold intensity of approximately 2.6 GW/cm(2) in our experiment. This method enables us to determine the TSRS threshold directly instead of measuring the TSRS gain coefficient and edge reflectivity of the crystals. (C) 2015 Optical Society of America
What problem does this paper attempt to address?