Quantitative Analysis of Polybrominated Diphenyl Ethers in Sewage Sludge
Chao YANG,Xiang-zhou MENG,Ling CHEN
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.06.026
2011-01-01
Abstract:Soxhlet extraction method,gel permeation chromatography column,multilayer silica and alumina column and GC-MS were used for quantitative analysis of polybrominated diphenyl ethers(PBDEs) in sewage sludge.A method of quality control and quality assurance(QC/QA) for the determination of PBDEs was developed.The recoveries for all 19 targets are 82% to 119%,and the recoveries of surrogates(BDE-50 and BDE-172) are(108±4.91)% and(99±4.72)% respectively.The instrumental detection limits for tri-to hepta-BDEs(namely BDE-17,28,33,47,49,66,99,100,138,153,154,183 and 190) are 0.55,0.46,0.52,0.33,0.36,0.22,0.14,0.33,0.24,0.10,0.14,0.27,and 1.5 pg respectively,and those for octa-to deca-BDEs(namely BDE-196,203,206,207,208 and 209) are 0.49,0.66,0.66,0.69,1.3 and 3.1 pg respectively.Based on the low method detection limits,satisfactory recoveries and good reproducibility,this method is suitable for determination of PBDEs in sludge samples from wastewater treatment plants.