Self‐gated free‐running 5D whole‐heart MRI using blind source separation for automated cardiac motion extraction
Isabel Montón Quesada,Augustin C. Ogier,Masaki Ishida,Masafumi Takafuji,Haruno Ito,Hajime Sakuma,Ludovica Romanin,Christopher W. Roy,Milan Prša,Jonas Richiardi,Jérôme Yerly,Matthias Stuber,Ruud B. van Heeswijk
DOI: https://doi.org/10.1002/mrm.30322
2024-10-11
Magnetic Resonance in Medicine
Abstract:Purpose To compare two blind source separation (BSS) techniques to principal component analysis and the electrocardiogram for the identification of cardiac triggers in self‐gated free‐running 5D whole‐heart MRI. To ascertain the precision and robustness of the techniques, they were compared in three different noise and contrast regimes. Methods The repeated superior–inferior (SI) projections of a 3D radial trajectory were used to extract the physiological signals in three cardiac MRI cohorts: (1) 9 healthy volunteers without contrast agent injection at 1.5T, (2) 30 ferumoxytol‐injected congenital heart disease patients at 1.5T, and (3) 12 gadobutrol‐injected patients with suspected coronary artery disease at 3T. Self‐gated cardiac triggers were extracted with the three algorithms (principal component analysis [PCA], second‐order blind identification [SOBI], and independent component analysis [ICA]) and the difference with the electrocardiogram triggers was calculated. PCA and SOBI triggers were retained for image reconstruction. The image sharpness was ascertained on whole‐heart 5D images obtained with PCA and SOBI and compared among the three cohorts. Results SOBI resulted in smaller trigger differences in Cohorts 1 and 3 compared to PCA (p
radiology, nuclear medicine & medical imaging