A Simple Sizing Algorithm for Stand-Alone Pv/Wind/Battery Hybrid Microgrids

Jing Li,Wei,Ji Xiang
DOI: https://doi.org/10.3390/en5125307
IF: 3.2
2012-01-01
Energies
Abstract:In this paper, we develop a simple algorithm to determine the required number of generating units of wind-turbine generator and photovoltaic array, and the associated storage capacity for stand-alone hybrid microgrid. The algorithm is based on the observation that the state of charge of battery should be periodically invariant. The optimal sizing of hybrid microgrid is given in the sense that the life cycle cost of system is minimized while the given load power demand can be satisfied without load rejection. We also report a case study to show the efficacy of the developed algorithm.
What problem does this paper attempt to address?