Decentralized Membrane Filtration System for Sustainable and Safe Drinking Water Supply in Low-Income Countries: Baseline Study

haiou huang,joseph g jacangelo,kellogg j schwab
DOI: https://doi.org/10.1061/(ASCE)EE.1943-7870.0000433
2011-01-01
Abstract:Decentralized membrane filtration systems (DMFS) have the potential to supply safe drinking water in low-income countries (LICs) where centralized municipal water treatment is practically infeasible. This study aimed at applying an integrated bench-scale and field-testing approach to assess the sustainability of a DMFS in producing safe drinking water in LICs. The state-of-the-art DMFS employed in this study was capable of removing bacteria, surrogate parasites, and viruses at log reductions above 7, 5, and 4, respectively, from evaluated waters (n=4). The technological sustainability of the DMFS was primarily affected by membrane fouling, and a linear correlation was found between the reversible/irreversible fouling rates of a miniature bench-scale system and those of the full-size DMFS caused by representative types of source waters. The total and irreversible fouling rates of the full-size DMFS were approximately 50% of those of the miniature system, regardless of the properties of the source waters. Similar quantitative relationships may be established between the fouling rates of the bench-scale system and those of other full-size DMFS. Overall, easy and cost-effective fouling control is warranted for sustainable application of DMFS in LICs, and bench-scale membrane testing serves as a potential screening tool for this purpose. DOI: 10.1061/(ASCE)EE.1943-7870.0000433. (C) 2011 American Society of Civil Engineers.
What problem does this paper attempt to address?