Predicting Failures of Suture Anchors Used for Rotator Cuff Repair: A Ct-Based 3-Dimensional Finite Element Analysis

Hirotaka Sano,Kei Imagawa,Nobuyuki Yamamoto,Hiroshi Ozawa,A. Toshimitsu Yokobori,Eiji Itoi
DOI: https://doi.org/10.3233/bme-151535
2015-01-01
Bio-Medical Materials and Engineering
Abstract:BACKGROUND: Failure of inserted anchors has been recognized as one of the major pathomechanisms of re-tearing after rotator cuff repair.OBJECTIVE: To predict the inserted anchor failure using CT-based 3-dimensional finite element method (CT/3D-FEM).METHODS: Among twenty patients who underwent rotator cuff repair, 5 had anchor failure (failed anchor group) and 15 had no anchor failure (stable anchor group). A 3D model of proximal humerus was developed for each patient based on the CT data. A virtual pullout testing of TWINFIX (TM) anchors inserted into bone at 6 different sites was performed using FEM. Then, mean failure load of 6 anchors for each patient was compared between two groups. Moreover, an optimal cut-off value of the mean failure load was determined for predicting anchor failure.RESULTS: The mean failure load in the failed anchor group (70.3 N) was significantly lower than that in the stable anchor group (119.0 N; p < 0.0001). In our method, the optimum cut-off value of the mean failure load was 75.4 N.CONCLUSIONS: Failure of the inserted TWINFIX (TM) anchor could be predicted using CT/3D-FEM. In this method, there seemed to be a high risk of anchor failure in shoulders with a mean failure load of < 75.4 N.
What problem does this paper attempt to address?