Matrix Solid-Phase Dispersion Coupled with Magnetic Ionic Liquid Dispersive Liquid-Liquid Microextraction for the Determination of Triazine Herbicides in Oilseeds.

Yuanpeng Wang,Ying Sun,Bo Xu,Xinpei Li,Xinghua Wang,Hanqi Zhang,Daqian Song
DOI: https://doi.org/10.1016/j.aca.2015.07.028
IF: 6.911
2015-01-01
Analytica Chimica Acta
Abstract:A novel method was developed for the determination of six triazine herbicides from oilseeds by matrix solid-phase dispersion combined with magnetic ionic liquid dispersive liquid-liquid microextraction (MSPD-MIL-DLLME), followed by ultrafast liquid chromatography with ultraviolet detection (UFLC-UV). The MIL, 1-butyl-3-methylimidazolium tetrachloroferrate ([C4mim][FeCl4]), was used as the microextraction solvent to simplify the extraction procedure by magnetic separation. The effects of several important experimental parameters, including type of dispersant, ratio of sample to dispersant, type and volume of collected elution solvent, type and volume of MIL, were investigated. Using the present method, UFLC-UV gave the limits of detection (LODs) of 1.20-2.72 ng g(-1) and the limits of quantification (LOQs) of 3.99-9.06 ng g(-1) for triazine herbicides. The recoveries were ranged from 82.9 to 113.7% and the relative standard deviations (RSDs) were equal or lower than 7.7%. The present method is easy-to-use and effective for extraction of triazine herbicides from oilseeds and shows the potentials of practical applications in the treatment of the fatty solid samples.