Step Response Identification under Inherent-Type Load Disturbance with Application to Injection Molding

Tao Liu,Feng Zhou,Yi Yang,Furong Gao
DOI: https://doi.org/10.1021/ie1015427
2010-01-01
Industrial & Engineering Chemistry Research
Abstract:Motivated by autotuning of injection velocity in an industrial injection molding machine, a step response identification method is proposed for practical application subject to inherent-type load disturbance. Both models of the process and the inherent-type load disturbance can be simultaneously derived from a step test. Identification algorithms are detailed for obtaining the widely used low-order models of first-order plus dead time (FOPDT) and second-order plus dead time (SOPDT). Based on the identified process and disturbance models, a two-degree-of-freedom (2DOF) internal model control (IMC) structure plus feed-forward control is proposed for improving load disturbance rejection. Analytical controller design formulas and tuning guidelines are developed accordingly. A practical application to the velocity control of an injection molding machine is shown to illustrate the effectiveness and merits of the proposed identification method and control strategy.
What problem does this paper attempt to address?