An FPGA-Based Modified Adaptive PID Controller for DC/DC Buck Converters

Ling Lv,Changyuan Chang,Zhiqi Zhou,Yubo Yuan
DOI: https://doi.org/10.6113/jpe.2015.15.2.346
2015-01-01
Abstract:On the basis of the conventional PID control algorithm, a modified adaptive PID (MA-PID) control algorithm is presented to improve the steady-state and dynamic performance of closed-loop systems. The proposed method has a straightforward structure without excessively increasing the complexity and cost. It can adaptively adjust the values of the control parameters (K-p, K-i and K-d) by following a new control law. Simulation results show that the line transient response of the MA-PID is better than that of the adaptive digital PID because the differential coefficient Kd is introduced to changes. In addition, experimental results based on a FPGA indicate that the MA-PID control algorithm reduces the recovery time by 62.5% in response to a 1V line transient, 50% in response to a 500mA load transient, and 23.6% in response to a steady-state deviation, when compared with the conventional PID control algorithm.
What problem does this paper attempt to address?