Abstract:The modulation transfer function (MTF) is one of the main criteria for judging the image quality of an imaging system. Together with the well-known optical transfer function, the MTF can be regarded as an objective basis reflecting the comprehensive performance of an imaging interferometer. In order to improve the imaging quality of a modified spatially modulated imaging interferometer (MSMII) with large optical path difference, the boundary conditions of an incident ray, at full field of view, along the x and y directions, respectively, are first calculated by the method of prism expansion, and then the exact expression of the pupil function of the MSMII is given. The two-dimensional MTF of the MSMII is obtained by the Fourier transform. Compared with previous studies, this work gives the two-dimensional MTF for the MSMII, and analyzes the effects of various parameters on the MTF. The optimal values of the incident angle i together with the acute angels beta(1) and beta(2) are chosen as i = 0 degrees and beta(1) = beta(2) = 45 degrees, respectively. If so, a high MTF is obtained, i.e. the imaging quality of the MSMII can satisfy the need of detecting upper atmospheric wind fields.
What problem does this paper attempt to address?