The Diagnostic Accuracy and Safety of 99Tcm-Mibi Myocardial Perfusion Imaging-a Retrospective Multicenter Study
王荣福,邱艳丽,王立勤,张春丽,王蒨,姚稚明,田月琴,何作祥,戴皓洁,王茜,张建华,张旭初,米宏志,郭芳,焦建,于治国,陈雯,孙晓昕,李河北,岳明纲,任凌
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2012.06.003
2012-01-01
Abstract:Objective To evaluate the diagnostic accuracy and safety of 99Tcm-MIBI MPI by retrospectively analyzing data from this multicenter study.Methods Participating centers included six hospitals:Peking University First Hospital,Beijing Fuwai Hospital of Chinese Academy of Medical Science and Peking Union Medical College,Anzhen Hospital of Capital Medical University,Beijing Hospital of Health Ministry,Beijing Tongren Hospital of Capital Medical University and Peking University People's Hospital.According to the inclusion and exclusion criteria,500 subjects (335 male,165 female,mean age (60.1 ±11.1) years) who underwent MPI between April 1998 and April 2006 were enrolled.All subjects were investigated with stress/rest MPI and CAG within 1 month.Stress test was performed with bicycle ergometry or with intravenous dipyridamole,adenosine or ATP.Perfusion defects on MPI were allocated to corresponding coronary arteries.During the stress and imaging period,any discomfort or symptoms were recorded.Coronary stenosis with ≥ 50% luminal narrowing was considered significant in CAG and taken as the gold standard.99Tcm-MIBI MPI results for the number of stenosed vessels,stenotic severity and coronary artery allocation were compared usingx2 test.Results There were 280 subjects that underwent exercise stress tests and the remaining 220 received pharmacological stress tests (117 adenosine,32 dipyridamole,71 ATP).Two hundred and forty-nine patients had significant coronary stenosis and 251 had normal CAG.Out of the 249 patients with positive CAG results,101 had one-vessel,66 had two-vessel and 82 had three-vessel disease.Significant stenosis of the LAD was present in 205 patients,144 had RCA stenosis and 130 had stenosis of the LCX.The sensitivity,specificity,accuracy,positive predictive and negative predictive values of MPI for detection of coronary artery disease were 65.1% (162/249),81.3% (204/251),73.2% (366/500),77.5% (162/209) and 70.1% (204/291),respectively.There was no significant difference in the detection sensitivity of MPI between one-vessel disease and two-vessel disease (52.5% (53/101) vs 65.2% (43/66),x2 =2.624,P > 0.05),while the sensitivity was significantly higher for three-vessel disease than that for one-vessel plus two-vessel disease (80.5% (66/82) vs 57.5% (96/167),x2 =12.801,P < 0.01).The sensitivities among coronary artery stenosis subgroups of 50%-59%,60%-69%,70%-79%,80%-89%,90%-99% were 38.8% (40/103),39.6% (19/48),43.4% (53/122),51.2% (41/80)and 52.7% (48/91),respectively and not significantly different (x2 =5.721,P > 0.05),while it was significantly higher in the subgroup with 100% stenosis (82.9% (29/35),x2 =18.362,P < 0.01).The sensitivity for LCX lesions was lower than that for LAD and RCA (x2 =7.619,P < 0.01),whereas the specificity and accuracy had no significant difference (x2 =0.758,4.471,both P > 0.05).Mild side-effects during the study were recorded in 21 patients and were relieved without medical treatment.Conclusion 99Tcm-MIBI MPI is accurate and safe for the detection of coronary artery disease.