Determination of Phenols in Waste Water for Benzenes Saturation Based on the Sol-gel Amperometric Biosensor

Li-feng LUI,Lan-chun WEI,Jin ZHAO
DOI: https://doi.org/10.3969/j.issn.1006-6144.2005.04.020
2005-01-01
Abstract:This paper studied amperometric tyrosinase carbon paste electrode based on sol-gel materials.The working potential of the tyrosinase electrode was 100 mV(vs.SCE).The solution pH was 5.40,and the response time was 3 min. Under these conditions,the detection limit was 1.0010~(-6)mol/L, and the linear range was 1.0010~(-6)~1.0010~(-4) mol/L,and the RSD was 1.04%. The (o-cresol,hydro-)quinone,catechol and p-chlorophenol had good response on the electrode,but (o-amninoanisole,) resorcinol,p-cresol,o-nitrophenol and 2,4-dinitrophenol.Organic interferences (such as benzene,methylbenzene and dimethylbenzene) had no significant effects.
What problem does this paper attempt to address?