Fluid Damping And Power Consumption Of Active Devices Used In Cooling Electronics

Huang Longzhong,Agrawal Smita,Simon Terrence,Zhang Min,Yeom Taiho,North Mark,Cui Tianhong
DOI: https://doi.org/10.1115/IMECE2012-88627
2013-01-01
Abstract:Active devices, such as synthetic jets and oscillating plate agitators were found to be effective in cooling of high-heat-flux electronics. These devices generate unsteady flows, thinning the thermal boundary layer and enhancing turbulent transport. However, the active devices cause extra power consumption due to flow friction and separation. It is important to understand the factors influencing power consumption in these devices if they are to be applied in cooling system designs. The present study analyzes fluid damping and power consumption in high-frequency (about 1000 Hz) synthetic jets and oscillating plate agitators driven by piezoelectric stacks. This analysis is done numerically, since it is difficult to measure fluid damping. In the simulations, the moving part of the active device is modeled with the moving wall boundary condition. The mesh is updated and the flow is calculated every time the moving part changes its position. The coherent vortex structures generated by theses active devices, like vortices in the synthetic jet cavity or in the oscillating plate tip gap region, are found to cause fluid damping and power consumption. Fluidic power consumption levels with different geometries and different operating frequencies and amplitudes are studied. A correlation is developed to predict fluidic power consumption at different operating conditions.
What problem does this paper attempt to address?