Assembly of confocal silicon pore optics mirror modules
Nicolas M. Barrière,Ljubiša Babić,Alex Bayerle,Luigi Castiglione,Maximilien J. Collon,Noë Eenkhoorn,David Girou,Ramses Günther,Enrico Hauser,Yvette Jenkins,Boris Landgraf,Laurens Keek,Ben Okma,Gregorio Mendoza Serano,Aniket Thete,Giuseppe Vacanti,Sjoerd Verhoeckx,Mark Vervest,Luc Voruz,Marco W. Beijersbergen,Marcos Bavdaz,Eric Wille,Ivo Ferreira,Sebastiaan Fransen,Mark Olde Riekerink,Jeroen Haneveld,Bart Schurink,Ronald Start,Coen van Baren,Evelyn Handick,Michael Krumrey,Giuseppe Valsecchi,Miranda Bradshaw,Vadim Burwitz,Ljubiša Babic,Mark O. Riekerink
DOI: https://doi.org/10.1117/12.2594171
2021-09-17
Abstract:The mirror modules composing Athena’s X-ray optics are made with the Silicon Pore Optics (SPO) technology. SPO is produced as stacks of 38 mirror plates, which are paired to form X-ray Optics Units (XOUs) following a modified Wolter I geometry. In the current design, a mirror module is composed of two confocal XOUs glued in between a pair of brackets that freeze the configuration and provide interfaces to the mirror structure. Mirror modules are assembled at the XPBF2 beamline of PTB at the synchrotron radiation facility BESSY II, using dedicated jigs. In this paper we present the latest developments regarding the assembly of confocal mirror modules for Athena with an emphasis on alignment tolerances and gluing accuracy.