Shape-based Diagnosis of the Aortic Valve

Razvan Ioan Ionasec,Alexey Tsymbal,Dime Vitanovski,Bogdan Georgescu,Shaohua Kevin Zhou,Nassir Navab,Dorin Comaniciu
DOI: https://doi.org/10.1117/12.812488
2009-01-01
Abstract:Disorders of the aortic valve represent a common cardiovascular disease and an important public-health problem worldwide. Pathological valves are currently determined from 2D images through elaborate qualitative evalu- ations and complex measurements, potentially inaccurate and tedious to acquire. This paper presents a novel diagnostic method, which identies diseased valves based on 3D geometrical models constructed from volumetric data. A parametric model, which includes relevant anatomic landmarks as well as the aortic root and lea ets, represents the morphology of the aortic valve. Recently developed robust segmentation methods are applied to estimate the patient specic model parameters from end-diastolic cardiac CT volumes. A discriminative distance function, learned from equivalence constraints in the product space of shape coordinates, determines the corresponding pathology class based on the shape information encoded by the model. Experiments on a heterogeneous set of 63 patients aected by various diseases demonstrated the performance of our method with 94% correctly classied valves.
What problem does this paper attempt to address?