Tdr Measurement System and The Application of Tdr in Geoenvironmental Engineering

renpeng chen,wei chen,yunmin chen
DOI: https://doi.org/10.1007/978-3-642-04460-1_9
2010-01-01
Abstract:Time domain reflectometry (TDR) is a fast, accurate, and safe technology. The basic principle of time domain reflectometry (TDR) is the same as radar. The system sends an electromagnetic pulse along the waveguide and reflects on the mismatch impedance. Therefore, The position of mismatch impedance can be determined from the reflected signal which can be used to monitoring the underground water level. Commonly useful information from TDR signal includes the apparent dielectric constant and the electrical conductivity. The dielectric constant can be utilized to determine the water content of soils and the dry density. The electrical conductivity of pore fluid is a strong indicator of the ionic concentration of contamination in soils and has s strong relationship with the strength of soft soils treated by LKD or cement, therefore, the TDR method is widely used to control the effect of the treated soils and monitor the ionic contaminant.
What problem does this paper attempt to address?