Study on the Change of Coagulation Factors Activity of Fresh Frozen Plasma Stored at -30℃ and -80℃ for One Year

张雪芹,丁培芳,滕彬,申华,申法奎,张萍
DOI: https://doi.org/10.3969/j.issn.1671-2587.2005.02.008
2005-01-01
Abstract:The aim of our study was to investigate the change of coagulation factors activity in FFP stored at two different temperatures during one year.Methods 16 plasma units were randomly selected,they were aliquoted and frozen at -30℃ and -80℃,respectively. One-stage methods were used to detect the coagulation factors on 0,90,180,270 and 360 d,respectively;the concentration of vWF and FⅧ∶CAg were assayed by immunoprecipitation method.Results All the measured coagulation factors showed an acceptable stability during the total storage at two different temperatures.There were no statistically significant loss for FⅪ∶C,FⅨ∶C,vWF and FⅧ∶CAg when FFP stored at -30℃ during one year.However,for FV∶C and FⅧ∶C a significant reduction was found,although the activity were not reduced below 70%. There were no significant changes for all coagulation factors measured when FFP stored at -80℃ during the total storage. Conclusion Our findings showed that FFP under storage temperature of -30℃ for one year is feasible.It can improve the preservation of labile coagulation factors when FFP stored at -80℃.
What problem does this paper attempt to address?