Application of Hollow Glass Waveguides in Urological Treatment

M Nemec,P Koranda,H Jelinkova,O Kohler,P Drlik,M Miyagi,YW Shi,Y Matsuura
DOI: https://doi.org/10.1117/12.588908
2005-01-01
Abstract:The application of specially designed delivery system consisted of cyclic olefin polymer coated silver hollow glass waveguide (inner/outer diameter 700/850 mu m) with protector in one side and sealed cap in the output is shown for treatment of ureter wall perforation by Er:YAG laser radiation. For this purpose Er:YAG laser system (wavelength 2.94 mu m) working in free-running and Q-switched regime was utilized. The basic characteristic of the interaction of Er:YAG laser radiation with the ureter surface and its deep structures was found. Maximum interaction pulse energy and length in free-running regime were 100mJ and 200 mu s. respectively (corresponding intensity 130 kW.cm(-2)). Maximum interaction pulse energy and length in Q-switched regime were 30mJ and 70 ns, respectively (corresponding intensity 111 MW.cm(-2)). From the histological evaluation it follows that the application of Q-switched Er:YAG laser radiation on ureter tissue resulted in minimum tissue alteration without any influence on the deeper layers.