Mitochondria-Directed Fluorescent Probe for the Detection of Hydrogen Peroxide near Mitochondrial DNA

ying wen,keyin liu,huiran yang,yi liu,liming chen,zhongkuan liu,chunhui huang,tao yi
DOI: https://doi.org/10.1021/acs.analchem.5b03326
IF: 7.4
2015-01-01
Analytical Chemistry
Abstract:It is important to detect hydrogen peroxide (H2O2) near mitochondrial DNA (mtDNA) because mtDNA is more prone to oxidative attack than nuclear DNA (nDNA). In this study, a mitochondria-targeted fluorescence probe, pep3-NP1, has been designed and synthesized. The probe contains a DNA-binding peptide, a H2O2 fluorescence reporter, and a positively charged red emissive styryl dye to facilitate accumulation in mitochondria. Due to groove binding of the peptide with DNA, the styryl dye of pep3-NP1 intercalated into the bases of DNA, leading to an increase in red fluorescence intensity (centered at 646 nm) and quantum yield. In this case, pep3-NP1 was a turn-on probe for labeling DNA. Subcellular locations of pep3-NP1 and MitoTracker suggested that pep3NP1 mostly accumulated in the mitochondria of live cells. Namely, as an intracellular DNA marker, pep3-NP1 bound to mtDNA. In the presence of H2O2, pep3-NP1 emitted green fluorescence (centered at 555 nm). Thus, the ratio of green with red fluorescence of pep3-NP1 was suitable to reflect the change of the H2O2 level near mtDNA in living cells. The detecting limit for H2O2 was estimated at 2.9 and 5.0 mu M in vitro and in cultured cells, respectively. The development of pep3-NP1 could help in studies to protect mtDNA from oxidative stress.
What problem does this paper attempt to address?