Determination of AFB1 in Corns by High Performance Liquid Chromatography Without Derivations

Chuang ZHOU,Xiao-Min BAN,Sheng-Li LIU,Hai-Bin ZHANG
DOI: https://doi.org/10.19812/j.cnki.jfsq11-5956/ts.2014.07.054
2014-01-01
Abstract:Objective To develop a method for the determination of AFB1 in the corns by high performance liquid chromatography (HPLC) without any derivations to make the determination process simpler. Methods The extraction, purification and detection conditions were optimized. Finally, an HPLC method without derivations was developed. Results When the concentrations of AFB1 were at 0.5~80μg/mL, a good linearity between the concentration and peak area ratio was obtained. The linear regression equation was Y=1095223X+857392 with R2=0.99884. The limit of detection was 0.60 ng/mL and recovery rates were between 86.40%and 99.06%. Relevance rate and the rate of exceeding the allowed standards of China in the 43 corn samples was 39.53% and 11.63%, respectively. Conclusion The HPLC without derivations could be used to detect the content of AFB1 in the corns, and it had simpler process, better operability and more practical application value.