Nonlinear Aerosol Lidar for Remote Detection and Identification of Bioaerosols in Clouds

G Mejean,F Courvoisier,J Kasparian,V Boutou,E Salmon,J Yu,JP Wolf
2004-01-01
Abstract:We demonstrate the first non-linear Lidar for rangeresolved detection and identification of biological aerosols in the air. Two-photon-excited fluorescence (2PEF) is induced in riboflaviin containing particles at a remote location by ultrashort Terawatt laser pulses. 2PEF-Lidar should be more efficient than 1PEF-Lidar for amino acids detection beyond a typical distance of 2 km, because it takes advantage of the higher atmospheric transmission at the excitation wavelengths. 2PEF-Lidar moreover allows size measurement by pump-probe schemes, and pulse shaping may improve the detection selectivity. Since laser-induced filaments are transmitted through aerosols, bioaerosols may be detected even inside dense clouds 1. NONLINEAR AEROSOL LIDAR The early detection and identification of potentially harmful bioagents in the air has become a major issue for both defence and public security reasons. This requires fast detection of the outbreak location, 3Dmapping of the plume as it propagates, and unambiguous identification of the agents among the broad variety of atmospheric background aerosols. In this letter, we study the application of fluorescencebased Lidar (Light Detection and Ranging) towards these goals. We demonstrate experimentally the first remote detection and identification of bioagent simulants (riboflavin-doped microparticles) in the air by non-linear Lidar. We used the 5 TW pulses (80 fs, 400 mJ at 800 nm) of the Teramobile [1,2] to induce in-situ two-photonexcited fluorescence (2PEF) [3] in ribovlavin-doped aerosol particles,. The bioagent simulants were produced with an aerosol generator located at 45 m from the Teramobile. Their size distribution and concentrations were monitored using an optical sizer (Grimm model G 1-108). They consisted of water droplets of 1 um size in average (typical for bacteria [4]) and containing 0.02 g/l riboflavin. The backward emitted fluorescence and scattered signals are collected by a 20 cm telescope, which focuses the light on a spectrally resolved detector. The returns are recorded as a function of the photons flight time, providing distance resolution. Two major reasons motivate the use of ultrashort multiphoton excitation: (1) the better atmospheric transmission at longer wavelengths (decrease of Rayleigh scattering and prevention of molecular absorption such as ozone) and (2) the possibility of simulatneous size measurement by pump-probe schemes [5,6], and coherent excitation with shaped pulses [7,8] to improve the detection selectivity. The results for 10 W/cm incident intensity on the target are shown in Fig. 1. The detected 2PEF spectrum clearly identifies the presence of riboflavin containing particles, and the Lidar range resolution allows the precise spatial localization of the biological aerosol plume. The spatial resolution is 45 cm, limited by the fluorescence lifetime of 3 ns for this transition [9]. Notice that the contrast against fluorescence of the background aerosols present in the air at the time of the measurement is excellent. The comparison with pure water microdroplets clearly demonstrates the capability of identifying biological particles from background nonbiological ones of the same size. These experiments show that the one photon per pulse detection limit corresponds to a concentration as low as 10 particles per cubic centimeter, for a 10 m spatial resolution. Using shorter wavelength excitation (around 530 nm) would provide significant advantages as compared to the 800 nm wavelength: (1) the already high sensitivity would be further enhanced by using 2PEF from the amino-acid tryptophan [4,10]. (Trp), the concentration of which is typically 10 times higher than riboflavin in bacterias (10 Trp molecules in a 1 μm particle [9]), and (2) two-photons at 530 nm would not only excite tryptophan, but also NADH and riboflavin, whose fluorescence features around 320-370 nm, 420-500 nm, and 520-620 nm, respectively, would provide multiple cross-checking biological signatures of the particle [10]. We performed numerical simulations to estimate the performance of a non-linear 2PEF Lidar, compared to a linear 1PEF-Lidar (emission wavelength 266 nm), in the case of tryptophan fluorescence detection. Although ultrashort Terawatt lasers that emit around 530 nm are not commercially available yet, recent developments in
What problem does this paper attempt to address?