Multi-quartz-enhanced Photoacoustic Spectroscopy

Yufei Ma,Xin Yu,Guang Yu,Xudong Li,Jingbo Zhang,Deying Chen,Rui Sun,Frank K. Tittel
DOI: https://doi.org/10.1063/1.4927057
IF: 4
2015-01-01
Applied Physics Letters
Abstract:A multi-quartz-enhanced photoacoustic spectroscopy (M-QEPAS) sensor system for trace gas detection is reported. Instead of a single quartz tuning fork (QTF) as used in QEPAS technique, a dual QTF sensor platform was adopted in M-QEPAS to increase the signal strength by the addition of the detected QEPAS signals. Water vapor was selected as the target analyte. M-QEPAS realized a 1.7 times signal enhancement as compared to the QEPAS method for the same operating conditions. A minimum detection limit of 23.9 ppmv was achieved for the M-QEPAS sensor, with a calculated normalized noise equivalent absorption coefficient of 5.95 × 10−8 cm−1W/√Hz. The M-QEPAS sensor performance can be further improved when more QTFs are employed or an acoustic micro-resonator architecture is used.