Atmospheric Air Diffuse Array-Needles Dielectric Barrier Discharge Excited by Positive, Negative, and Bipolar Nanosecond Pulses in Large Electrode Gap

Li Zhang,De-zheng Yang,Wen-chun Wang,Zhi-jie Liu,Sen Wang,Peng-chao Jiang,Shuai Zhang
DOI: https://doi.org/10.1063/1.4895982
IF: 2.877
2014-01-01
Journal of Applied Physics
Abstract:In this paper, positive, negative, and bipolar nanosecond pulses are employed to generate stable and diffuse discharge plasma using array needles-plate electrode configuration at atmospheric pressure. A comparison study of discharge images, electrical characteristics, optical emission spectra, and plasma vibrational temperature and rotational temperatures in three pulsed polarity discharges is carried on under different discharge conditions. It is found that bipolar pulse is beneficial to the excitation of diffuse dielectric barrier discharge, which can generate a room temperature plasma with more homogeneous and higher discharge intensity compared with unipolar discharges. Under the condition of 6 mm electrode gap distance, 26 kV pulse peak voltage, and 150 Hz pulse repetition rate, the emission intensity of N2 (C3Πu → B3Πg) of the bipolar pulsed discharge is 4 times higher than the unipolar discharge (both positive and negative), while the plasma gas temperature is kept at 300 K, which is about 10–20 K lower than the unipolar discharge plasma.
What problem does this paper attempt to address?