Precise Measurement of Liquid-Level by Fiber Loop Ring-Down Technique Incorporating an Etched Fiber

Yajun Jiang,Wei Jiang,Biqiang Jiang,Abdul Rauf,Chuan Qin,Jianlin Zhao
DOI: https://doi.org/10.1016/j.optcom.2015.03.031
IF: 2.4
2015-01-01
Optics Communications
Abstract:A method for precise measurement of the liquid-level by using a fiber loop ring-down technique incorporating a short section of etched fiber is proposed and experimentally demonstrated. The change of liquid-level is obtained by recording the ring-down time τ of light in the fiber loop. The experimental results show that the liquid-level has a well defined linear relationship with the inverse of τ over the range of 1cm; the relative standard deviation of τ is about 0.21% and correspondingly the least detectable liquid-level change is about 4µm by using an etched fiber with diameter of 25.1µm. Moreover, this method has low temperature cross-sensitivity when the refractive index of liquid is higher than that of the fiber cladding, so it can be employed for liquid-level measurement with high resolution.
What problem does this paper attempt to address?