Automated Hollow-Fiber Liquid-Phase Microextraction Coupled with Liquid Chromatography/Tandem Mass Spectrometry for the Analysis of Aflatoxin M-1 in Milk

Siming Huang,Du Hu,Ying Wang,Fang Zhu,Ruifen Jiang,Gangfeng Ouyang
DOI: https://doi.org/10.1016/j.chroma.2015.09.012
IF: 4.601
2015-01-01
Journal of Chromatography A
Abstract:An automated hollow fiber liquid-phase microextraction (HF-LPME) coupled with liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the extraction and determination of aflatoxin M-1 (AFM(1)) in milk samples. Parameters affecting the extraction efficiency, such as the extraction phase, matrix conditions, extraction time and temperature, were investigated. Under the optimal conditions (ratio of water to milk, 4:1; extraction time, 50 min; extraction temperature, 50 degrees C; extraction phase, 50 mg L-1 anti-AFM(1) antibody in PBS buffer solution; volume of HCl solution, 250 mu L; agitation speed, 250 rpm), the matrix-matched calibration curve for AFM(1) determination showed good linearity in the range of 0.25-5 mu g kg(-1). The enrichment factor (EF) reached 48, and the limits of detection and quantification were 0.06 and 0.21 mu g kg(-1), respectively. The developed method was successfully applied for the extraction of AFM(1) from spiked milk samples, with recoveries from 61.0% to 106.7%. The method was highly specific to AFM(1) analysis, and the results demonstrated that the method can be automated, inexpensive, and free from interference. (C) 2015 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?