Thermal Performance of a Traditional Chinese Heated Wall with the In-Series Flow Pass: Experiment and Modeling

Pengsu Wang,Ming Yang,Xudong Yang,Ming Shan
DOI: https://doi.org/10.1016/j.enbuild.2014.07.075
IF: 7.201
2014-01-01
Energy and Buildings
Abstract:Chinese heated wall is a traditional space heating device commonly used in the northeast rural China. It absorbs and stores the surplus heat of high temperature smoke from solid fuel combustion in the stove, and releases the heat to room gradually in the following hours. In this article, a full-scale heated wall was constructed for measuring its thermal performances. The experimental results show that the heated wall could recover approximately 70% of the surplus heat from the stove under the measurement conditions. A dynamic heat transfer model considering heat transfer between the hot smoke and the wall body and the room was also developed. The simulated temperatures agreed well with the experimental data. Therefore, the model could be applied to analyze the thermal performance and optimize the design of the heated wall in future. (C) 2014 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?